The IT servers for a medium-sized company need to be protected from grid failures (e.g. blackout) and thus is powered through an uninterruptable power supply (UPS) unit. The UPS consists of a 3- phase diode rectifier powering the dc bus, which then splits between a 3-phase inverter unit and a battery energy storage system (BESS). UPS parameters are given in Table B2 and a general schematic is shown in Figure B2. Assuming that the inverter and BESS pull a combined constant current, IDC, from the dc bus, draw the approximate waveforms over one full ac cycle for: (i) the three ac line voltages, (ii) the three ac currents, and (iii) the total dc bus voltage. Explain how the single-phase inverter operates and draw an approximate waveform of the load-side ac voltage. Comment on the chosen switching frequency for the inverter. Choose a dc/dc converter topology for the BESS. Draw the converter diagram for your chosen topology and justify each of your design choices. Estimate the battery capacity (in kWh) needed to sustain grid failure for 48 hours under full load. Comment on your answer. Main input voltage Rated total power Inverter switching frequency Output voltage Power efficiency BESS voltage 400 V, 3-phase 8 kW 10 kHz 230 V, single phase 93.3% (full load) 800 V

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
Question
The IT servers for a medium-sized company need to be protected from
grid failures (e.g. blackout) and thus is powered through an
uninterruptable power supply (UPS) unit. The UPS consists of a 3-
phase diode rectifier powering the dc bus, which then splits between a
3-phase inverter unit and a battery energy storage system (BESS). UPS
parameters are given in Table B2 and a general schematic is shown in
Figure B2.
Assuming that the inverter and BESS pull a combined constant current,
IDC, from the dc bus, draw the approximate waveforms over one full ac
cycle for: (i) the three ac line voltages, (ii) the three ac currents, and
(iii) the total dc bus voltage.
Explain how the single-phase inverter operates and draw an
approximate waveform of the load-side ac voltage.
Comment on the chosen switching frequency for the inverter.
Choose a dc/dc converter topology for the BESS. Draw the converter
diagram for your chosen topology and justify each of your design
choices.
Estimate the battery capacity (in kWh) needed to sustain grid failure for
48 hours under full load. Comment on your answer.
Main input voltage
Rated total power
Inverter switching frequency
Output voltage
Power efficiency
BESS voltage
400 V, 3-phase
8 kW
10 kHz
230 V, single phase
93.3% (full load)
800 V
Transcribed Image Text:The IT servers for a medium-sized company need to be protected from grid failures (e.g. blackout) and thus is powered through an uninterruptable power supply (UPS) unit. The UPS consists of a 3- phase diode rectifier powering the dc bus, which then splits between a 3-phase inverter unit and a battery energy storage system (BESS). UPS parameters are given in Table B2 and a general schematic is shown in Figure B2. Assuming that the inverter and BESS pull a combined constant current, IDC, from the dc bus, draw the approximate waveforms over one full ac cycle for: (i) the three ac line voltages, (ii) the three ac currents, and (iii) the total dc bus voltage. Explain how the single-phase inverter operates and draw an approximate waveform of the load-side ac voltage. Comment on the chosen switching frequency for the inverter. Choose a dc/dc converter topology for the BESS. Draw the converter diagram for your chosen topology and justify each of your design choices. Estimate the battery capacity (in kWh) needed to sustain grid failure for 48 hours under full load. Comment on your answer. Main input voltage Rated total power Inverter switching frequency Output voltage Power efficiency BESS voltage 400 V, 3-phase 8 kW 10 kHz 230 V, single phase 93.3% (full load) 800 V
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,